Inverter

Residential Hybrid Inverter 6kW

EAHI6KSL-S

Hybrid inverter specification Typical application Battery specification

Specifications

MODEL EHB48314D10S1P
Rated output power 6000VA/6000W
Dimensions(W×H×D)(mm) 700×81.5×405
Weight(kg) 4.8
Battery voltage 51.2Vdc
Energy capacity 10kWh
Certification IEC 62619, IEC 63056, UN 38.3

Detailed Specifications

Hybrid inverter specification

MODELEAHI6KSL-S
PV input parameter
Max. input power8000W
Max. input voltage550Vdc
Starting voltage150Vdc
Max. input current16/16A
Short circuit current24/24A
Number of input strings per MPPT1/1
AC input/output parameters(grid side)
Input voltage range184-276Vac
Input frequency range50±5Hz/60±5Hz
Max. input current40A
Rated output power6000W
Max. apparent output power6000VA
Grid system mode1/N/PE
Rated output voltage220Vac/230Vac
Rated output frequency50Hz/60Hz
Rated output current27.3A/26.1A
Power factor>0.99(0.8 lead~0.8 lag)
AC output parameters(back-up side)
Rated output power6000VA/6000W
Grid system mode1/N/PE
Rated output voltage230Vac(208/220/240Vac settable)
Rated output frequency50Hz/60Hz
Rated output current27.3A/26.1A
THDv≤3%(linear load)
Switching time≤10ms
Efficiency
Maximum efficiency97.8%
MPPT efficiency99.9%
Protection
ComprehensiveGrid over-voltage protection, grid over-frequency protection, grid overload protection, over-temperature protection, anti-islanding protection, insulation resistance detection, residual current monitoring unit, output over-current protection, output short-circuit protection, surge protection
Surge protectionDC Type II/AC Type III
Inverter standard
LVDIEC/EN 62109-1/-2, AS62109
EMCEN 61000-6-1/-2/-3/-4
Grid-tiedCEI 0-21, DIN VDE V 0124-100:2020, VDE-AR-N 4105:2018, NRS097-2-1, EN 50549-1, G99/1-9:2022, ETSI EN303645+PSTI, C10/11:2021, XP C 15-712-3:2019, ELOT EN 50549-1:2019, PEA
Inverter other parameters
Dimensions(W×H×D)(mm)700×530×405
Weight(kg)41.4

Battery specification

MODELEHB48314D10S1P
Cell technologyLiFePO4
Battery voltage51.2Vdc
Max. expandable number4
Energy capacity10kWh
Cell type314Ah
Scalable capacity range10kWh~40kWh
DODMax. 100% DOD(settable)
Max. charging power5KW@1 module, 6kW@>1 module
Max. discharging power5KW@1 module, 6kW@>1 module
Max. charging current100A
Max. discharge current105A@1 module, 120A@>1 module
Communication interface485 and CAN
CertificationIEC 62619, IEC 63056, UN 38.3
Dimensions(W×H×D)(mm)700×250×405
Weight(kg)83
Base parameters
Dimensions(W×H×D)(mm)700×81.5×405
Weight(kg)4.8