Onduleur

Onduleur hors réseau 3-5kW

GF3K24H/GF3K24L/GF5K48H/GF5K48L

Onduleur hors réseau GF3K24H/GF3K24L/GF5K48H/GF5K48L monophasé

Paramètres techniques

Modèle GF3K24H | GF3K24L | GF5K48H | GF5K48L
Puissance nominale 3000VA/3000W | 5000VA/5000W
Tension nominale 24VDC | 48VDC
Dimensions (L×P×H) (mm) 322×122×390 | 342×122×471 | 332×142×420
Poids net (kg) 9 | 11 | 12
Indice de protection IP20

Detailed Specifications

Inverter specification

MODELGF3K24HGF3K24LGF5K48HGF5K48L
Rated power3000VA/3000W5000VA/5000W
Parallel functionNoYes, 6 units max
AC input
Rated input voltage230VAC120VAC230VAC120VAC
Input voltage range170~280VAC PC90~280VAC home application90~140VAC170~280VAC PC90~280VAC home application90~140VAC
Rated input frequency50/60Hz self-adapting
Input frequency range40~65Hz
Rated input current20A36A32A61.33A
Max. input current30A40A40A80A
AC output
Rated AC output voltage230VAC120VAC230VAC120VAC
Output settable voltage220V/230V/240V100V/110V/120V220V/230V/240V100V/110V/120V
Output settable frequency50Hz/60Hz
Rated AC output current13.05A25.00A21.70A41.67A
Overload capacityInverter output: 10s@110%~150% rated load; 5s@≥150% rated load; 100ms@≥200% rated loadPower grid output: 5s@≥150% rated load; 100ms@≥200% rated load
THDv<5%, linear load; <10%, non-linear load
Efficiency(peak value)93%
Surge power6000VA, 5 cycles10000VA, 5 cycles
Switching time10ms(Typical)
Battery
Battery typeLead-acid battery/lithium battery
Rated voltage24VDC48VDC
Charging voltage27VDC(default)24~29.2VDC settable54VDC(default)48~58.4VDC settable
Overcharge protection voltage30.2VDC60.5VDC
Rated discharge current130A113.7A
PV/AC charging
PV chargingMPPT
Max. PV plate power4000W6000W
Max. PV plate open circuit voltage450VDC
MPPT operation range voltage120~430VDC
Max. PV input current18A27A
Max. PV charging current100A
Max. AC charging current100A
Max. battery charging current100A
Others
Dimension(W×D×H)(mm)322×122×390342×122×471332×142×420
Net weight(kg)91112
Operating environment-10°C~50°C
IP ratingIP20
ProtectionsInput over/under voltage protection, input over/under frequency protection, output overload,output short-circuit, radiator overtemperature protection, fan fault detection etc.
Communication interfacesUSB/RS485, dry contact, WiFi(optional)USB/RS232/RS485, dry contact,WiFi(optional)USB/RS485, dry contact,WiFi(optional)
Contactez-nous